ECCN.DEV by Cancelli

3B903 Category 3B

Scanning Electron Microscope (SEM) equipment designed for imaging semiconductor devices or integrated circuits, having all of the following (See List of Items Controlled).

Category 3: Electronics

Reasons for control

Country chart

ControlColumn
AT applies to entire entryAT 1
NS applies to entire entryNone
RS applies to the entire entryNone

List-based license exceptions

ExceptionAs stated in the entry
GBS N/A IEC: Yes, see § 740.2(a)(22) and § 740.24 of the EAR.
LVS N/A

Items

  1. Related Definition: N/A
  2. a. Stage placement accuracy less (better) than 30 nm;
  3. b. Stage positioning measurement performed using laser interferometry;
  4. c. Position calibration within a field-of-view (FOV) based on laser interferometer length-scale measurement;
  5. d. Collection and storage of images having more than 2 x 10 8 pixels;
  6. e. FOV overlap of less than 5 percent in vertical and horizontal directions;
  7. f. Stitching overlap of FOV less than 50 nm; and
  8. g. Accelerating voltage more than 21 kV.

Related controls

See ECCNs 3D901 for related “development” or “production” “software”, ECCN 3E901 for related “development” and “production” “technology”.

Notes

Note 1: 3B903 includes SEM equipment designed for chip design recovery.

Note 2: 3B903 does not apply to SEM equipment designed to accept a Semiconductor Equipment and Materials International (SEMI) standard wafer carrier, such as a 200 mm or larger Front Opening Unified Pod (FOUP).

Source: eCFR, version 2026-08-01, retrieved 2026-08-20T04:04:59+00:00.