ECCN.DEV by Cancelli

2B119 Category 2B

Balancing machines and related equipment, as follows (see List of Items Controlled).

Category 2: Materials Processing

Reasons for control

Country chart

ControlColumn
AT applies to entire entryAT 1
MT applies to entire entryMT 1

List-based license exceptions

ExceptionAs stated in the entry
GBS N/A
LVS N/A

Items

  1. a. Balancing machines having all of the following characteristics:
  2. a.1. Not capable of balancing rotors/assemblies having a mass greater than 3 kg;
  3. a.2. Capable of balancing rotors/assemblies at speeds greater than 12,500 rpm;
  4. a.3. Capable of correcting unbalance in two planes or more; and
  5. a.4. Capable of balancing to a residual specific unbalance of 0.2 g mm per kg of rotor mass.
  6. b. Indicator heads designed or modified for use with machines specified in 2B119.a.

Related controls

See also 7B101.

Notes

Note: 2B119.a. does not control balancing machines designed or modified for dental or other medical equipment.

Note: Indicator heads are sometimes known as balancing instrumentation.

Source: eCFR, version 2026-08-01, retrieved 2026-08-20T04:04:59+00:00.