ECCN.DEV by Cancelli

6A205 Category 6A

“Lasers,” “laser” amplifiers and oscillators, other than those controlled by 6A005 (see List of Items Controlled), excluding items that are subject to the export licensing authority of the Nuclear Regulatory Commission (see 10 CFR part 110).

Category 6: Sensors and Lasers

Reasons for control

Country chart

ControlColumn
AT applies to entire entryAT 1
NP applies to entire entryNP 1

List-based license exceptions

ExceptionAs stated in the entry
GBS N/A
LVS N/A

Items

  1. Items: a. Copper vapor lasers having both of the following characteristics:
  2. a.1. Operating at wavelengths between 500 nm and 600 nm; and
  3. a.2. An average output power equal to or greater than 30 W;
  4. b. Argon ion “lasers” having both of the following characteristics:
  5. b.1. Operating at wavelengths between 400 nm and 515 nm; and
  6. b.2. An average output power greater than 40 W;
  7. c. Neodymium-doped (other than glass) lasers with an output wavelength between 1000 nm and 1100 nm having either of the following:
  8. c.1. Pulse-excited and Q-switched with a pulse duration equal to or greater than 1 ns, and having either of the following:
  9. c.1.a. A single-transverse mode output with an average output power greater than 40 W; or
  10. c.1.b. A multiple-transverse mode output with an average output power greater than 50 W; or
  11. c.2. Incorporating frequency doubling to give an output wavelength between 500 nm and 550 nm with an average output power of greater than 40 W.
  12. d. Tunable pulsed single-mode dye laser oscillators having all of the following characteristics:
  13. d.1. Operating at wavelengths between 300 nm and 800 nm;
  14. d.2. An average output greater than 1 W;
  15. d.3. A repetition rate greater than 1 kHz; and
  16. d.4. Pulse width less than 100 ns;
  17. e. Tunable pulsed dye laser amplifiers and oscillators having all of the following characteristics:
  18. e.1. Operating at wavelengths between 300 nm and 800 nm;
  19. e.2. An average output greater than 30 W;
  20. e.3. A repetition rate greater than 1 kHz; and
  21. e.4. Pulse width less than 100 ns;
  22. f. Alexandrite lasers having all of the following characteristics:
  23. f.1. Operating at wavelengths between 720 nm and 800 nm;
  24. f.2. A bandwidth of 0.005 nm or less;
  25. f.3. A repetition rate greater than 125 Hz; and
  26. f.4. An average output power greater than 30 W;
  27. g. Pulsed carbon dioxide “lasers” having all of the following characteristics:
  28. g.1. Operating at wavelengths between 9,000 nm and 11,000 nm;
  29. g.2. A repetition rate greater than 250 Hz;
  30. g.3. An average output power greater than 500 W; and
  31. g.4. Pulse width of less than 200 ns;
  32. h. Pulsed excimer lasers (XeF, XeCl, KrF) having all of the following characteristics:
  33. h.1. Operating at wavelengths between 240 nm and 360 nm;
  34. h.2. A repetition rate greater than 250 Hz; and
  35. h.3. An average output power greater than 500 W;
  36. i. Para-hydrogen Raman shifters designed to operate at 16 micrometer output wavelength and at a repetition rate greater than 250 Hz.;
  37. j. Pulsed carbon monoxide lasers having all of the following characteristics:
  38. j.1. Operating at wavelengths between 5,000 and 6,000 nm;
  39. j.2. A repetition rate greater than 250 Hz;
  40. j.3. An average output power greater than 200 W; and
  41. j.4. Pulse width of less than 200 ns.

Related controls

(1) See ECCNs 6E001 (“development”), 6E002 (“production”), and 6E201 (“use”) for technology for items controlled under this entry. (2) Also see ECCNs 6A005 and 6A995. (3) See ECCN 6A005.a.2 for additional controls on argon ion lasers; See ECCN 6A005.b.6.c for additional controls on neodymium-doped lasers. (4) “Lasers” “specially designed” or prepared for use in isotope separation are subject to the export licensing authority of the Nuclear Regulatory Commission (see 10 CFR part 110).

Notes

Note to 6A205.e: 6A205.e does not control single mode oscillators.

Note to 6A205.g: 6A205.g does not control the higher power (typically 1 kW to 5 kW) industrial CO2 lasers used in applications such as cutting and welding, as these latter lasers are either continuous wave or are pulsed with a pulse width greater than 200 ns.

Note to ECCN 6A205.j: 6A205.j does not control the higher power (typically 1 kW to 5 kW) industrial CO lasers used in applications such as cutting and welding, because such lasers are either continuous wave or are pulsed with a pulse width greater than 200 ns.